Mettler Toledo Titrator Karl Fischer EVA C3 D
Advanced coulometric Karl Fischer titrator with automated solvent exchange, LabX integration, and high-throughput automation for precise trace moisture analysis.
- Accurate trace water determination with diaphragm generator electrode
- Automated solvent exchange and balance integration for efficient workflows
- Compatible with LabX™ software and InMotion KF autosamplers
Introduction
The Mettler Toledo Titrator Karl Fischer EVA C3 D provides precise and automated trace water determination for various laboratory samples. It is designed for modern analytical laboratories that require accuracy, efficiency, and reliable data management.
The system combines advanced coulometric Karl Fischer titration with automated solvent exchange, intelligent user management, and seamless balance integration. Additionally, compatibility with LabX™ software and InMotion KF autosamplers improves productivity, data integrity, and regulatory compliance. Therefore, the EVA C3 D is an excellent solution for pharmaceutical, chemical, petrochemical, and quality control laboratories.
EVA C3 D Advanced Coulometric Karl Fischer Titration System
The METTLER TOLEDO EVA C3 D is an advanced instrument designed for precise trace water analysis across a wide range of sample types.
The complete system includes the main unit, terminal, generator electrode with diaphragm, titration vessel kit, and automated solvent exchange system. Together, these components create a safer and more efficient Karl Fischer workflow.
Key Features and Benefits
The EVA C3 D offers several features that simplify laboratory operations and improve measurement reliability:
- Advanced coulometric Karl Fischer titration: Provides accurate trace moisture determination for demanding applications.
- Automated solvent exchange: Reduces manual handling and improves laboratory safety.
- Innovative cell design: Simplifies cleaning procedures and minimizes cross-contamination risks.
- Direct balance integration: Transfers sample weights automatically, reducing transcription errors and improving accuracy.
- Flexible operation: An extendable terminal cable allows remote operation outside fume hoods.
- Enhanced automation: Supports InMotion KF Six, Flex, and Pro oven autosamplers for high-throughput analysis.
- Secure user management: Provides customizable access rights for controlled instrument operation.
- LabX™ software compatibility: Supports centralized data management, 21 CFR Part 11 compliance, and ALCOA++ principles.
Moreover, the EVA C3 D delivers fast and reliable water determination for laboratories that require consistent analytical performance.
Advanced Automation and Laboratory Efficiency
The EVA C3 D improves productivity through intelligent automation features. The automated solvent exchange system uses the dPumpKF technology to simplify reagent handling and reduce operator involvement.
Furthermore, the system integrates with METTLER TOLEDO balances for automatic sample weight transfer. As a result, users can reduce manual data entry and improve measurement consistency.
For laboratories handling large sample volumes, compatibility with InMotion KF Six, Flex, and Pro oven autosamplers enables efficient processing of challenging samples. Consequently, the EVA C3 D supports higher throughput while maintaining excellent accuracy.
Data Integrity and Compliance Support
The EVA C3 D helps laboratories maintain secure and traceable analytical workflows. Its comprehensive user management system allows administrators to assign customized access permissions.
Additionally, LabX™ Software provides centralized control of measurement data, instrument settings, and analytical processes. The software supports regulatory requirements, including 21 CFR Part 11 compliance and ALCOA++ data integrity principles.
Therefore, laboratories can improve documentation, maintain audit readiness, and strengthen overall quality management.
Why Choose METTLER TOLEDO EVA C3 D?
The METTLER TOLEDO EVA C3 D Coulometric Karl Fischer Titrator combines accuracy, automation, and intelligent data management for demanding analytical environments.
Its diaphragm generator electrode ensures precise coulometric Karl Fischer titration, while the automated solvent exchange system improves safety and reduces manual tasks. Additionally, the innovative titration cell design minimizes cleaning requirements and lowers contamination risks.
Direct balance integration automatically transfers sample weights, which helps eliminate transcription errors. Furthermore, compatibility with InMotion KF autosamplers supports efficient analysis of high-volume and complex samples.
Advanced user management protects instrument settings and ensures controlled operation. Meanwhile, LabX™ software enables centralized data handling, regulatory compliance, and improved process control.
Together, these capabilities make the EVA C3 D a dependable Karl Fischer titration solution for pharmaceutical, chemical, petrochemical, and quality control laboratories.
Related products
Jar Tester
Reliable Jar Tester with independent stirring control, adjustable speed (10–300 rpm), and durable epoxy-coated structure for precise coagulation and flocculation analysis.
- Independent stirring control for multiple samples
- Adjustable speed range: 10–300 rpm
- Durable epoxy-painted metal and stainless-steel construction
Total Chlorine PRO Photometer
Fast and reliable Total Chlorine PRO Photometer with ±0.06 mg/L accuracy, built-in timer, error messaging, and user-friendly cuvette chamber for consistent results.
- Accurate chlorine measurement 0.00–5.00 mg/L
- Built-in timer ensures consistent reaction time
- Portable, rugged design for field and lab use
- Error messaging prevents testing mistakes
Hanna Benchtop pH Meter
High-precision Hanna Benchtop pH Meter with dual channels, auto temperature compensation, and multiparameter measurement for laboratory and industrial applications.
- Measures pH, ORP, ISE, EC, TDS, salinity, and temperature
- Dual independent input channels for simultaneous testing
- Automatic temperature compensation and wide measurement ranges
FiveGo pH Meter Mettler Toledo
- Measures pH 0-14 with ±0.01 accuracy.
- IP67 watertight and dustproof design.
- 3.1" LCD for clear readings.
- Lightweight at 260 g for portability.
The FiveGo pH meter F2, Mettler Toledo measures pH (0-14) and ORP with ±0.01 accuracy. Featuring an IP67 rating and a 3.1" LCD, it’s ideal for lab testing from 0°C to 100°C.
PH Electrode Mettler Inlab Expert Pro-ISM
- Measures pH 0-14 accurately.
- Automatic sensor recognition feature.
- Durable PEEK shaft design.
- Wide 0°C-100°C temperature range.
The pH Electrode Mettler Inlab Expert Pro-ISM measures pH 0-14 with a robust PEEK shaft and automatic recognition. Ideal for beer, soil, and water testing, it operates from 0°C to 100°C.
Electrode for PH Meter
- Measures pH 0-14 accurately.
- Robust POM shaft design.
- BNC/RCA connector for compatibility.
- Low-maintenance gel electrolyte system.
The Electrode for pH Meter ensures accurate pH measurement (0-14) in water, beer, and soil samples. With a robust POM shaft and BNC/RCA connector, it operates within 0°C-80°C for reliable testing

Reviews
There are no reviews yet.