pH electrodes designed for small sample volumes or for measuring in small containers.
- For use with METTLER TOLEDO Seven Excellence and Seven Compact meters as well as other brands. (Connection cable is not included; sold separately.)
- Intelligent Sensor Management (ISM) electrodes capture and save calibration data, which is then automatically recognized by the meter once connected.
- Capture electrode calibration and results with LabX software, designed for advanced data management and 21CFR part 11 regulatory compliance.
- Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples.
Featured Applications
- Vials
- Microplates
- Test tubes
- Serum and Gastric juice
- Micro-biological samples
- Paint
- Gel
- Soap
- Shampoo
- Cosmetics
Electrode Specifications
- InLab Micro: ceramic junction; refillable with 3M KCl (51350072) – keep probe filled with electrolyte for accurate results
- InLab Micro Pro-ISM: ceramic junction; refillable with 3M KCl (51350072) – keep probe filled with electrolyte for accurate results
- InLab Ultra-Micro-ISM: ceramic junction; refillable with FRISCOLYT-B™ (51343185) – keep probe filled with electrolyte for accurate results
- InLab Semi-Micro: ceramic junction; non-refillable – replace when electrolyte depleted
- InLab Semi-Micro-L: ceramic junction; refillable with 3M KCl (51350072) – keep probe filled with electrolyte for accurate results
- InLab Flex-Micro: porous PTFE junction; non-refillable – replace when electrolyte depleted
Accessories & Care
- Store in 3M KCl (51350072) or InLab Storage Solution (30111142)
- Recommended for use with METTLER TOLEDO buffers (Sachets: 51302080, Bottles: 63056116)
Specifications
| Description | pH Electrode InLab Ultra-Micro-ISM |
| Connector Types | Multi-Pin |
| Junction | Ceramic |
| Material | Glass |
| pH Range | 1 to 11 |
| Type | Combination Electrode |
| For Use With (Application) | Measuring small sample volumes in very small vessels such as vials, micro plates and cuvettes |
| For Use With (Equipment) | Requires Cable, Multi-Pin to BNC/RCA (30281896) |
| Internal Reference | ARGENTHAL™ with Ag+-trap |
| Membrane | LoT Glass |
| Model | InLab™ Ultra-Micro-ISM |
| Response Time | <20 sec. |
| Storage Requirements | InLab storage solution |
| Temperature (Metric) Range | 0°C to 80°C |
| Volume (Metric) Sample | 15 μL |
| Length (Metric) | 40 mm |
| Length (Metric) Stem | 40 mm |
| Diameter (Metric) | 3 mm |
Related products
Jar Tester
Reliable Jar Tester with independent stirring control, adjustable speed (10–300 rpm), and durable epoxy-coated structure for precise coagulation and flocculation analysis.
- Independent stirring control for multiple samples
- Adjustable speed range: 10–300 rpm
- Durable epoxy-painted metal and stainless-steel construction
ATAGO PAL-3 Refractometer
ATAGO PAL-3 refractometer ensures quick, accurate Brix readings with automatic temperature compensation, durable glass prism, and IP65 water-resistant design.
- Automatic temperature compensation (ATC)
- Water calibration and easy cleaning (IP65)
- Accurate Brix readings in 3 seconds
- Durable optical glass prism
Digital Refractometer
Fast, accurate Digital Refractometer with automatic temperature compensation, IP65-rated, stainless steel prism, and Brix-to-Baumé conversion for food, wine, and syrup.
- Measures Brix and Baumé with high accuracy
- IP65 dust- and water-resistant design
- Fast readings using just 2–3 drops of sample
- Automatic temperature compensation for reliable results
TSS Meter Portable
Hach Portable TSS Meter with multi-beam infrared technology ensures precise turbidity and solids measurement. Durable stainless steel probe with sapphire window resists harsh conditions.
- Measures turbidity, TSS, and sludge blanket levels
- Automatic air-bubble compensation for accuracy
- Durable stainless steel body with sapphire window
- Wide range: TSS 0.001–400 g/L, Turbidity 0.001–9999 FNU
Hanna Benchtop pH Meter
High-precision Hanna Benchtop pH Meter with dual channels, auto temperature compensation, and multiparameter measurement for laboratory and industrial applications.
- Measures pH, ORP, ISE, EC, TDS, salinity, and temperature
- Dual independent input channels for simultaneous testing
- Automatic temperature compensation and wide measurement ranges
Buffer Solution pH-4, 7, 10 Mettler Toledo
- pH values: 4.01, 7.00, 10.00.
- ±0.02 pH accuracy.
- 250ml jar, 24-36 months shelf life.
- Single bottle per pack.
The Buffer Solution pH-4, pH-7, pH-10, 250ml Per Jar, Mettler Toledo offers pH 4.01, 7.00, and 10.00 in 250ml jars for precise calibration. With ±0.02 accuracy and a 24-36 month shelf life, it’s ideal for lab use.
Electrode for PH Meter
- Measures pH 0-14 accurately.
- Robust POM shaft design.
- BNC/RCA connector for compatibility.
- Low-maintenance gel electrolyte system.
The Electrode for pH Meter ensures accurate pH measurement (0-14) in water, beer, and soil samples. With a robust POM shaft and BNC/RCA connector, it operates within 0°C-80°C for reliable testing